            EN ISO11997-1循環(huán)腐蝕試驗標(biāo)準(zhǔn)(鹽霧、干燥、潮濕)

            時間:2018/11/24閱讀:7856
            分享:

            undefined
             

            L24

            L7
             

             

                                                               Cycle A

            C.1 Salt fog test solution

            Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.

             

            C.2 Cycle

            Set up the cabinet to perform the following cycle.

             

            Step

            Time H

            Temp

            Condition

            Notes

            1

            2

            35±2

            Salt spray

             

            2

            4

            60±2

            Dry20-30%

             

            3

            2

            50±2

            Wet95%RH or over

             

            4

            Go back to step 1

            This makes a total cycle time of 8h from step1 to step3

             

            Transtition timeie time allowed to reach the temperature and relative humidity specified for a condition after changing to that condition):

            From salt spray to drywithin 30min

            From dry to wetwithin 150 min

            From wet to salt spraywithin 30min

            The effect of the salt spray will,in principle,be instaneous。

            For details of drying-air flowsee 6.4

            NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.

             

            C3 Salt fog depsiton rate

            The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)

            C 4 Duration

            Unless otherwise agreed,repeat the test cycle for 30 cycles(240h),60cycles(240h),90cycles(720h) or 180cycles(1440h)

             

             

             

             

             

             

             

                                         Cycle B

            C.1 Salt fog test solution

            Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.

             

            C.2 Cycle

            Set up the cabinet to perform the following cycle.

            Step

            Time

            Temp

            Condition

            notes

            1

            24

            35±2

            Salt fog

             

            2

            8

            40±2

            100%RH

            Water condensing on test panels

            3

            16

            23±2

            50±20%RH

             

            4

            8

            40±2

            100%RH

            Water condensing on test panels

            5

            16

            23±2

            50±20%RH

             

            6

            8

            40±2

            100%RH

            Water condensing on test panels

            7

            16

            23±2

            50±20%RH

             

            8

            8

            40±2

            100%RH

            Water condensing on test panels

            9

            16

            23±2

            50±20%RH

             

            10

            48

            23±2

            50±20%RH

             

            11

            Go back to step 1

            This makes the total cycle time 7 days from step1 to step10.

            NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.

             

             

            C3 Salt fog depsiton rate

            The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)

            C 4 Duration

            Unless otherwise agreed,repeat the test cycle for 840 h

             

             

             

             ECS2017_3
             

             

             

             

             

             

                                            Cycle C

            C.1 Salt fog test solution

            Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (0.31±0.01)g/l and (4.1±0.01)g/l respectively  .The PH of the solution shall be in the range 6 to 7.

             

            C.2 Cycle

            Set up the cabinet to perform the following cycle.

            Step

            Time

            min

            Temp

            Condition

            notes

            1

            210

            30±2

            Salt fog

             

            2

            210

            40±2

            Dry

            Drying-air purge(see 6.4)

            3

            1470

            40±2

            75±15%RH

            One method of achieving this conditon is to alternate the dry and humid cycles for suitable(short)time periods to keep the RH between the limits specified

            4

            102

            30±2

            Dry

            Drying-air purge(see 6.4)

            5

            210

            30±2

            Salt fog

             

            6

            378

            30±2

            90% to 100%RH

            Water condensing on test panel

            7

            180

            35±2

            Dry

            Drying-air purge(see 6.4)

            8

            120

            25±2

            Dry

             

            9

            Go back to step 1

            This makes the total cycle time 48h from step1 to step8.

            NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.

             

             

            C3 Salt fog depsiton rate

            The salt fog deposition rate shall be 2ml/h to 4ml/h,when the salt fog iscollected over a 24h period (see Clause 10)

             

            C 4 Duration

            Unless otherwise agreedrepeat the test cycle for1000h

             

             

             

             

                                               Cycle D

            C.1 Salt fog test solution

            Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.

             

            C.2 Cycle

            Set up the cabinet to perform the following cycle.

             

            Step

            Time H

            Temp

            Condition

            Notes

            1

            0.5

            30±2

            Salt spray

             

            2

            1.5

            30±2

            Wet:(95±3%RH

             

            3

            2

            50±2

            Hot dry

             

            4

            2

            30±2

            Warm dry

             

            5

            Go back to step 1

            This makes a total cycle time of 6h from step1 to step4

             

            Transtition timeie time allowed to reach the temperature and relative humidity specified for a condition after changing to that condition):

            From salt spray to wetwithin 10min

            From wet to hot drywithin 15 min

            From hot dry to salt warm drywithin 30min

            From salt warm dry to salt sprayinstaneous

            NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.

             

            C3 Salt fog depsiton rate

            The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)

             

            C 4 Duration

            Unless otherwise agreed,repeat the test cycle for 28 cycles(168h)