狠狠色丁香久久综合婷婷亚洲成人福利在线-欧美日韩在线观看免费-国产99久久久久久免费看-国产欧美在线一区二区三区-欧美精品一区二区三区免费观看-国内精品99亚洲免费高清

            產(chǎn)品展廳收藏該商鋪

            您好 登錄 注冊

            當前位置:
            東莞市勤卓環(huán)境測試設備有限公司>技術文章>FLTM BO 116-01_2007

            技術文章

            FLTM BO 116-01_2007

            閱讀:1320          發(fā)布時間:2019-8-27

            FLTM BO 116-01_2007

            本頁面標準信息均來源于網(wǎng)絡收集,或由參與標準制定的供應商提供,只作為參考使用,為確保測試結(jié)果的準確性、節(jié)省您的時間,如需FLTM BO 116-01_2007標準詳細信息或FLTM BO 116-01_2007具體測試方法,請與我們技術人員聯(lián)系或給我們留言,我們將為您提供相關的技術支持。

             

            FLTM-BO-116-01標準簡介

            FLTM-BO-116-01 汽車內(nèi)飾材料暴曬試驗標準:水冷式氙弧燈氣候試驗箱方法

            FLTM  BO 116-01_2007標準英文版

            EXPOSRE OF INTERIOR TRIM MATERIALS IN A CONTROLLED IRRADIANCE

            WATER COOLED XENON-ARC APPARATS

            Application

            This procedure is used to determine the effects of simulated weather on interior trim materials using a controlled irradiance water cooled xenon-arc Weather-Ometer® with an auxiliary lantern and filters.

            Apparatus Required

            Operating Filter

            335 nm long pass filters (SF-5 filters) or equivalent provided the transmission spectrum is within 95% of the SF-5 filter transmission at all wavelengths. The filters are reversible unless otherwise marked by a coating or etching.

            Dimensions for the Ci 5000 series Weather-Ometer®:

            339 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

            Dimensions for the Ci 3, Ci 6 & Ci 4000 Weather-Ometer®:

            220 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

            Lamp Sensor Irradiance Filter

            420 nm Irradiance Filter

            Available from:

            Atlas Material Testing Technology LLC

            4114 Ravenswood Ave.

            Chicago, IL 60613 SA

            Calibration Lamp

            The calibration lamp must be calibrated to 420 nm with the lantern assembly removed.

            Available from:

            Atlas Material Testing Technology LLC

            4114 Ravenswood Ave.

            Chicago, IL 60613 SA

            Sample & Test Conditions

            Sample Conditioning

            All test values indicated herein are based on material conditioned in a controlled atmosphere of 21 +/-2 °C and 50 +/- 5% relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified.

            Test Conditions

            Testing conditions such as black panel temperature, dry bulb temperature, humidity, light cycle times and dark cycle times are equivalent to those outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Table 1,Section 6.1.5.

            Place the 335 nm long pass filters (SF-5 filters) or equivalent into the auxiliary lantern. Orient thelantern around the xenon-arc lamp assembly which is equipped with the Quartz/Type "S" Borosilicate filtered xenon-arc lamp source as outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Apparatus Set-p, Section 6.

            Exposures are monitored based on measured light at 1.06 W/m2 -/nm@420 nm SAE J2412 –Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance XenonArc Apparatus, Table 1.

            Calibration

            Equipment Calibration

            As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A, Section A.3 and Appendix B.

            Maintenance

            Equipment Maintenance

            As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A.

            Note: SF-5 auxiliary filters should be cleaned at every lamp calibration period or more frequent if necessary.

            SF-5 filters and the 420 nm interference filter should be changed per the manufacturer's recommendations/or within 13,000 hours of use.

            Exposure

            Sample Exposure

            As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Test Procedure, Section 7.

            Evaluation & Reporting

            Sample Evaluation and Exposure Report

            As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Evaluating and Reporting, Section 8 and Exposure Report, Section 9.

            AATCC Gray Scale, 10 Step, According to AATCC Evaluation Procedure 1/ISO 105-A02 for Evaluation of Color Change.

            FLTM BO II--01_2007測試機構(gòu)

             

            pon request measure the gloss with a 60° glossmeter (or as specified in the applicable Engineering Standard) according to FLTM BI 110-01. Record the unexposed and exposed gloss.

            Chemicals, materials, parts and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

            收藏該商鋪

            登錄 后再收藏

            提示

            您的留言已提交成功!我們將在第一時間回復您~

            對比框

            產(chǎn)品對比 產(chǎn)品對比 聯(lián)系電話 二維碼 意見反饋 在線交流

            掃一掃訪問手機商鋪
            189-2580-2250
            在線留言